Machine at glance
Automatic PET blower with infra-red heating system and bottle transfer
conveyor produces 1800 & 2000 bph with 4-cavity and 3000 bph with six- cavity. Flexible machine can be used for 4-cavity up to 1 liter and 2-cavity up to 2 liter and then single cavity up to 5 liters.Advantages
- Higher production at lower capital cost
- Finish bottle is not handled by operator
- Bottle output is on conveyor (BIS Requirement)
- Lowest conversion cost.
Note: Wide Mouth JAR attachment can also be provided with this model.
|
|
|
|
|
|
|
|
| |
|
|
Features:
PAUTO-1800 |
|
| |
|
|
Blowing Product |
Bottle |
|
Blowing Capacity |
0.2 -2 liters |
|
Mould Cavity |
4 |
|
Neck Size (max) |
30 mm |
|
Production Rate |
1800- 2000 BPH |
|
Operator |
One & Two |
|
Heating Power |
21 KWS |
|
Max Connecting Load |
50 KWS |
|
Process |
Preform loading is manual all other automatic, bottle
ejections on conveyor automatic. |
|
Automation |
Automatic blown bottle
ejection in three piece mould. |
|
|
|
|
 |
|
|
|
|
Auxiliary Equipment
Specification |
|
|
|
Air Compressor – 01 No each |
High Pressure Air
dryer with oil and air micron filter (optional) - 01 No. |
|
|
|
|
Type |
Motor |
Max. Pressure |
F.A.D. |
Receiver |
|
High Pressure Compressor |
20 HP
|
30.0 BAR |
37.7 CFM |
500 LTR. |
|
Low Pressure
Compressor |
15 HP |
12.5 BAR |
45.00 CFM |
500 LTR. |
|
| Type |
Refrigerated Air Dryer |
| Cfm | 40 CFM of Air |
| Air pressure |
40 KG / SQCM |
| Others |
With Compressor, Comdensor and
Filters |
| Inlet temp. |
4-5 DEGREE CENTIGRADE |
| Outlet temp. |
2.5 DEGREE CENTIGRADE |
|
|
|
|
|
01 Ton Water Chiller – 01 No. |
20 KVA/3 Phase Stabilizer (optional) – 01 No. |
|
|
|
| Water Flow Rate |
25 LPM / 1500 LPH |
| Inlet temp. |
14
DEGREE CENTIGRADE |
| Oulet temp. |
10
DEGREE CENTIGRADE |
| Electrical Connection |
415V(+5), 50 HZ, 3Phase, 4 Wire AC Supply |
| Type of chiller plant |
Mobiled Air Cooled |
| Cooling Capacity |
6000 KCAL/HR |
| Refrigerant Cooling Media |
AIR, FREON R-22 |
| Chiller |
Coil Type Chiller |
| Chiller Circulation Pump |
0.5 HP |
|
| Input |
295 V
to 410V, 3Phase, 4 Wire, 50 HZ Unbalce |
| Output |
415 V + - 1%, 3Phase, 50HZ |
| Cooling |
A.N. |
| O/p Voltage Adjust |
+ - 10 V by
means of Potentio Meter |
| Controls |
Auto / Manual |
| Specification |
O/V & U/V TRIP
Overload & Shortcircuit Protection by MCB
Voltmeter to see I/P & O/P Voltages
Ammeter to see the Load currents
Built in single phase preventer |
| Indication |
Mains O/N, O/P ON, O/V, U/V Single
phasing trip |
| App. Dimensions |
W 800MM, D 400MM, H 800MM |
|
|
|
|
|
|
|